KAPAT
SIKO Wire-actuaded Encoders SG20

SIKO Wire-actuaded Encoders SG20

Measurement Range 0 ... 2000 mm
Housing Die cast zinc
Operating Voltage 10 … 30 V DC
Output Current 4 … 20 mA
Weight 0.32 kg
Measured Distance / Rope Drum Revolution 100 mm
Protection Category IP65
Ambient Temperature -10 … 80 °C
Storage Temperature ±0.15 mm
Speed 0 … 10 V DC
Mechanical data
FeatureTechnical dataAdditional information
Housingzinc die-cast
Wire designsteel wire (stainless steel) ø0.45 mmplastic coated
Extension force≥2 N

T1 operating temperature

≥11 N

T2 working temperature

Measured distance/ rope drum revolution100 mm
Absolute accuracy±0.35 %relating to measuring length (mm)
Cable length≤30 m

4/20mA, MWIHP, MWIHP/R encoder type

≤20 m

P10; 0/10V; 0,5/4,5V encoder type

Weight~0.32 kg
Electrical data
Encoder potentiometer
FeatureTechnical dataAdditional information
Power rating2 W at 70 °C
Resistance10 kΩ
Resistance tolerance±5 %
Linearity tolerance±0.25 %
Transducer, power output
FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DC

between I+ and I-, at ≤500 Ω load

Output current4 … 20 mA

(4/20mA; MWIHP)

Transducer, voltage output
FeatureTechnical dataAdditional information
Operating voltage15 … 28 V DC

at 3 mA without load (0/10V)

8 … 28 V DC

at 3 mA without load (0,5/4,5V)

Output voltage0 … 10 V DC

ILoad ≤10 mA

0.5 … 4.5 V DC

ILast ≤10 mA (0,5/4,5V)

Resistance2 … 10 kΩ

against GND

Load≤15 mA

Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range.  The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA (MWI) or 0 … 10 V DC (MWU) is available. 

System data
FeatureTechnical dataAdditional information
Repeat accuracy±0.15 mm
Travel speed≤1 m/s
Ambient conditions
FeatureTechnical dataAdditional information