Working Principle |
Through beam sensors |
Size |
M18x1 (plug) |
Design |
Screw |
Emitted Light |
Infrared, 880 nm, clocked |
Service Voltage |
10 ... 30 V DC |
No-load Current |
30 mA |
Operating Distance |
0 ... 10000 mm |
Sensitivity Adjustment |
Potantiometer |
Switching Output |
pnp, 100 mA, NO/NC |
Switching Frequency |
333 Hz |
Response/Release Time |
1,5 ms / 1,5 ms |
Ambient Temperature |
-25 … +55 °C |
Ambient Light Immunity |
3 kLx, clocked light, 10 kLx, sun light |
Protection Category |
IP 67 |
Protection Degree |
III, protective low voltage operation |
Housing |
ABS |
Material |
polymethyl methacrylate (window) |
Type of Connection |
Connector, M12, 4-pole |
Evaluation |
Digital |